YS ROII Hemodialysis Reverse Osmosis Water Treatment Unit (0.5T-3T)

Model: YS-ROII Series
Place of Origin: Anhui,China (Mainland)
Capacity Range:: 0.5T/H to 3T/H
Compliance:: YY0572-2015, YY/T0793.1-2022, YY/T1269-2015
Technology:: Dual-Stage Reverse Osmosis
Control System:: 10-inch HMI Touchscreen

inquiry

basketAdd to Basket  Edit

Share |

Product Description

Payment & Shipping Terms Supply Capacity
Trade Term:FOB,CIP,CPT,EXWPacking:Packed in Export...
Payment Terms:Paypal, L/C, D/P, D/A, T/T, WUDelivery Date:60 days
Means of Transport:Ocean, Air, Land

  • Full Regulatory Compliance: Guaranteed adherence to YY0572-2015, YY/T0793.1-2022, and other critical Chinese medical standards.

  • Advanced Dual-Stage RO: Superior contaminant rejection for the highest purity water, ensuring patient safety.

  • Intelligent 10" HMI Control: User-friendly touchscreen for real-time monitoring, data logging, and system control.

  • Scalable & Reliable: A range of models (0.5T-3T/H) to precisely match the needs of clinics to large hospitals (1-70 beds).

  • Comprehensive Water Quality Monitoring: Integrated conductivity table for continuous water quality assurance.


The YS-ROII Series represents the pinnacle of water treatment technology specifically engineered for the critical demands of hemodialysis and related therapies. In hemodialysis, water quality is not just a requirement; it is a matter of patient safety. Our systems are meticulously designed and manufactured to meet and exceed the most stringent international and Chinese medical standards, including YY0572-2015 for water quality and YY/T0793.1-2022 for equipment preparation and quality management. We provide a reliable, turnkey solution for generating ultrapure dialysis water, giving healthcare professionals absolute confidence in the treatment they deliver.


Every component of the YS-ROII system is selected and integrated with one goal: to produce consistently pure water that is safe for patient contact. The system is built to comply with Routine Control Requirements (YY/T1269-2015), ensuring that every unit performs reliably day in and day out. By integrating technologies that align with Reverse Osmosis Water Treatment Equipment standards (GB/T19249-2017) and using terminology defined in GB/T13074-2009, we ensure operational excellence and industry familiarity.


The core mission of the YS-ROII system is to remove all harmful contaminants present in the feed water. Chemicals, bacteria, endotoxins, and ionic impurities can have devastating consequences for dialysis patients. Our system is engineered to eliminate these risks. The product water consistently meets the chemical and microbiological purity levels mandated by YY0572-2015, ensuring that every milliliter of water used in dialysate preparation is of the highest possible quality. This commitment to purity helps protect patients from pyrogenic reactions, long-term toxicity, and other serious health complications, making the YS-ROII an indispensable guardian of patient well-being.


The YS-ROII is built around a robust and intelligent architecture. The heart of the system is its advanced dual-stage reverse osmosis configuration. This two-pass process provides an exceptional barrier against contaminants, offering a much higher level of purification than single-stage units. The first RO stage removes the bulk of the dissolved solids, organics, and microorganisms, while the second stage polishes the water to achieve the ultra-purity required for hemodialysis.


This is all managed by a state-of-the-art centralized control system featuring a 10-inch Human-Machine Interface (HMI) touchscreen. This intuitive interface provides medical staff with complete oversight and command of the water production process. Operators can view real-time parameters like conductivity, pressure, and flow rates, access historical data for compliance and troubleshooting, and receive immediate alerts for any system anomalies. The automated control logic manages system startup, flush cycles, and shutdown, simplifying operation and reducing the potential for human error.


We understand that a one-size-fits-all approach does not work in healthcare. A small nephrology clinic has different needs than a large specialized hospital. The YS-ROII series is offered in a comprehensive range of capacities, from 0.5 tons per hour to 3 tons per hour. This scalability allows you to select a model that perfectly matches your patient load and water consumption, ensuring operational efficiency and cost-effectiveness. Our systems are designed to reliably support everything from a single dialysis bed to large centers with 60-70 beds, providing a future-proof solution that can grow with your facility's needs.


To ensure optimal performance and longevity, the YS-ROII system is designed to work with standard municipal tap water that complies with the Standard for drinking water quality (GB5749-2022). The feed water should have a total dissolved solids (TDS) content of less than 500 ppm, with an incoming water pressure between 2 to 5 kg/cm² and a temperature range of 5-45°C. By specifying these parameters, we ensure the system operates at peak efficiency, minimizing maintenance needs and maximizing the lifespan of critical components like the RO membranes.


The YS-ROII Series is the trusted choice for:

  • Healthcare Institutions: Hemodialysis centers, specialized nephrology hospitals, and nephrology departments within general hospitals.

  • Research and Development: Medical research facilities and biomedical organizations conducting research related to blood purification and dialysis therapies.

  • Invest in the YS-ROII Hemodialysis Water Treatment System—where technological innovation meets unwavering commitment to patient safety. Contact us today to find the perfect model for your application and ensure your facility delivers the highest standard of care.


WATER TREATMENT EQUIPMENT FOR HEMODIALYSIS INFORMATION TABLE

ModelYS-ROII-0.5TYS-ROII-1TYS-ROII-1.5TYS-ROII-2TYS-ROII-2.5TYS-ROII-3T
ApplicationsHemodialysis centersHemodialysis centersHemodialysis centersHemodialysis centersHemodialysis centersHemodialysis centers
Water output≥0.5T≥1T≥1.5T≥2T≥2.5T≥3T
Design criteriaAs per YY0572-2015 Water for haemodialysis and related therapiesAs per YY0572-2015 Water for haemodialysis and relatedAs per YY0572-2015 Water for haemodialysis and relatedAs per YY0572-2015 Water for haemodialysis and relatedAs per YY0572-2015 Water for haemodialysis and relatedAs per YY0572-2015 Water for haemodialysis and related
Reverse osmosis technologyDual-stagetherapies Dual-stagetherapies Dual-stagetherapies Dual-stagetherapies Dual-stagetherapies Dual-stage
Conductivity TablePresentPresentPresentPresentPresentPresent
Control system10″ HML10″ HML10″ HML10″ HML10″ HML10″ HML
No. of bed(s)1-2020-3030-4040-5050-6060-70


Category: Water Treatment Equipment For Hemodialysis


«