YS-D Series 10L30L Medical Ultrapure Water Purification System

Model: YS-D-(10-30)AL/H
Place of Origin: Anhui,China (Mainland)
Water Production Capacity: 10L/h 30L/h
Technology: Single-Stage Reverse Osmosis (RO) System
Water Tank: Built-in integrated storage tank
Water Quality Standard: GB/T 6682-2008 (China First-Class Laboratory Standard)
Resistivity: 15-18 25C
Ion Removal Rate: 99.6%
Display: Digital resistivity meter for continuous monitoring
Power Supply: 220V/50Hz (customizable)
Applications: Medical laboratories, clinical analyzers, biochemical labs, pharmaceutical research centers, and hospital
Structure: Compact modular design for easy installation and maintenance

inquiry

basketAdd to Basket  Edit

Share |

Product Description

Payment & Shipping Terms Supply Capacity
Trade Term:FOB,DAT,CIP,CPTPacking:Packed in Export...
Payment Terms:L/C, D/P, D/A, T/TDelivery Date:60 days
Means of Transport:Ocean, Air, Land

Built-in water tank ensures stable water supply and purity

Produces ultrapure water with resistivity of 1518 Mcm  25C

Complies with GB/T 6682-2008 First-Class Laboratory Water Standard

High ion removal rate of 99.6% for maximum purity

Compact modular design for space-saving installation

Easy operation with digital resistivity meter and clear display

Ideal for medical, laboratory, and pharmaceutical applications

Low maintenance, energy-efficient single-stage RO system

Product Summary (≤90 characters)


The YS-D-(1030)AL/H Series Medical Ultrapure Water Purification System represents the next generation of compact, efficient, and high-performance water purification solutions designed specifically for medical and laboratory use. Built around a single-stage reverse osmosis (RO) system, this model delivers consistent and reliable ultrapure water that fully complies with the Chinese laboratory water standard GB/T 6682-2008 (First-Class).


Constructed with a durable and hygienic design, the YS-D system features an integrated water tank that ensures constant water availability while maintaining stable water quality. The advanced RO membrane effectively removes dissolved ions, organic compounds, and bacteria from the feed water, achieving an impressive ion removal rate of 99.6%. The resulting ultrapure water exhibits a resistivity of 1518 Mcm at 25C, ensuring it meets the strictest demands of analytical and clinical applications.


This system is ideal for use in medical and biochemical laboratories, hospitals, and pharmaceutical facilities where water purity is essential for accurate test results and sterile environments. It is widely used for preparing reagents, rinsing glassware, feeding autoclaves, supporting biochemical analyzers, and conducting high-precision experiments that demand ultrapure water quality.


The built-in resistivity meter provides real-time monitoring of water purity, ensuring users can track system performance easily. The intuitive display and user-friendly control interface make operation simple and efficient, reducing downtime and maintenance costs. The systems compact modular construction allows for flexible installation even in limited spaces, while its robust internal components ensure long-term reliability and consistent output.


Each YS-D-(1030)AL/H system undergoes strict factory calibration and quality testing to guarantee compliance with international laboratory standards. Its single-stage RO process not only minimizes energy consumption but also simplifies maintenance compared to multi-stage systems, providing a cost-effective and environmentally friendly solution for medical facilities.


Whether your goal is to ensure the purity of reagents, maintain contamination-free testing environments, or meet regulatory requirements for medical-grade water, the YS-D-(1030)AL/H series provides the reliability, accuracy, and convenience that modern laboratories demand. With precision engineering, exceptional ion removal efficiency, and seamless integration into laboratory workflows, this system is a dependable choice for professionals who cannot compromise on water quality.


EQUIPMENT WORK FLOW CHART


EOUIPMENT PARAMETERINFORMATION

EQUIPMENT PARAMETERS AND RELEVANT REQUIREMENTS
Equipment modelYS-DI-(10-30)AL/HWater quality standardsGB/T 6682-2008
Water output
10L-30L/H
Quality of water production
Electrical resistivity (25° C), MQ· cm≥15-18MQ·cm
Electrical conductivity(25℃), mS/m0.005
Absorbency (254nm, 1cm optical distance)0
Soluble silicon content (as Si2), mg/L<0.01
Oxidizable substance content (in O), mg/L<0.08
Evaporation residue content 105°℃±2°℃, mg/L0.6
Membrane desalination rate99.99%.
Additional information
Equipment size30*47*98cm
Influent requirements Water pressure Water temperature Power supply
Incoming water pressure≥0.2MPa
Water temperature5-45℃
Power supplyAC220V±10% 50HZ, with 24V safety voltage
Rated power(0.15-0.2) kw
Scope of application
Atomic absorption/fluorescence/laboratory/clinical lab; Fully automatic biochemical/luminescent
immune equipment water supply; High-precision electrochemical configuration water/battery cells/storage battery/chip water; Water supply for constant quantitative analysis/medicine, etc.


EQUIPMENT CHARACTERISTICS AND ADVANTAGES

Category: Clinical laboratory ultrapure water equipment